Fire hydrant flow testing software

Model press release for fire hydrant inspections and flow testing. The course is instructed by terry melnyk of wolseley waterworks group. A fire hydrant flow test is a process of flowing water out of at least one fire hydrant while obtaining the required pressures static, residual, and pitot needed to calculate the amount of water in gallons per minute gpm that the water system is capable of providing between the tested hydrants. Our mep engineers find every task simple and we achieve our best at affordable rates and a faster turnaround than our competitors. Fireflow and hydrant analysis determines the hydrant flow at a specified residual pressure and creates printable fire flow graphs and hydrant reports. The hydrant in the circle is the flow test procedures. Spreadsheet for single or multiple hydrant flow tests.

Recommended procedures and use of fire hydrant flow tests presented by. This software was developed to keep track of all the information that is. How to conduct a fire hydrant flow test spectrum fire. The fire department rolls up to the building, sirens blaring. Software for water water, wastewater, hydrant, meter. Therefore it is not necessary to include hydrants in your model to calculate fire flows since junctions can be used. Performing a fire hydrant flow test provides the actual static pressure, residual pressure and the flow from the hydrant. A fire hydrant flow test is a process of flowing water out of at least one fire hydrant while obtaining the required pressures static, residual, and pitot needed to calculate the amount of water in gallons per minute gpm that the water system is. Hydrant flow test fire hydrant flow test report tool. Hydrant flow testing is an routine requirement of australian standards and ensure your fire protection system performs when you need it to.

According to water experts, the multihydrant flow test method is the best and most. This data is critical to establishing an ongoing flow testing and maintenance. Hydrant flow tests are conducted to determine water availability in planning for firefighting activities, fire sprinkler systems or domestic water demand. Trackit software turns your pc into a real time data acquisition system by allowing you to stream graphical or tabular data directly to your pc capability varies by model. Invaluable for hydrant testing, pump testing, flushing and water main condition testing. Fire hydrant flow testing, fire flow tests, and hydrant testing are important ways to measure aspects of a water supply system. Simple hydraulic calculator fire sprinkler hydraulic calculation software. Com specializes in fire flow testing for private, residential and government. The telog hpr32a is an ideal pressure monitoring solution for pressure concerns, fire flow testing and hydraulic model calibration. Inspection, testing, and maintenance of waterbased fire protection systems and ii. Residual reading at pressure hydrant b pressure during.

Kypipe allows fire flow calculations to be made at hydrants, junctions or both. Recommended practice for fire flow testing and marking of. The tests are also useful in determining the general condition of the water distribution system by detecting closed valves or wall deposits. The flow test results are depicted on graphs with a vertical axis scaled in arithmetic units and. In addition, it is also necessary to perform a flow test to properly design a fire sprinkler system for a commercial or residential structure. Fire flow tests the primary function of fire flow tests is to determine water pressure and flow producing capabilities for fighting fires at any location within a. Standard for determining the fire flow rate available occurs at. Please contact us for consulting or questions about fire hydrant flow test analysis and residual pressure. Product details since 2000, ej has had a constant vision on the advancement and accuracy of flow testing. Fire hydrant flow testing, safety inspections, valve exercising, gis. The residual pressure will need to be charted to record the flow in gpm at 20 psi. Trimble unity software combined with telog wireless hydrant pressure recorders provide a giscentric cloud and mobile platform for monitoring system pressures, transients and trends, min, max and average pressure history at any user defined interval.

Nov 08, 2018 performing a fire hydrant flow test provides the actual static pressure, residual pressure and the flow from the hydrant. Flow testing hydrants annually will ensure flow pressures are adequate to fight fires. Nfpa 291 provides guidance on fire flow tests and marking of hydrants in order to determine and indicate the relative available fire service water supply from hydrants and to identify possible deficiencies which could be corrected to ensure adequate fire flows as needed. The hydrant capacity flow test is not included in either nfpa 291, recommended practice for fire flow testing and marking of hydrants, or awwa m17, installation, field testing, and maintenance of fire hydrants. Field guide hydrant flow tests videorecording library catalog. Crispladew can provide maintenance and repair for all types fire hydrants. During the fire hydrant flow test, we will collect the following information. Insure a reliable water supply for your customers, lower your iso score, and insure that you have enough water to fight. If you are performing fire flow tests of hydrants, use this test residual hydrant and flow hydrant are the same one.

Model phl hydrant meter locks are designed to easily secure fire hydrant meters and caps quickly and effectively. Cad utilities autolisp routines for shc compatibility. Take readings simultaneously after pressure at the residual hydrant has stabilized d. Ats digitally documents hydrant function, flow capability and test data with track one software.

Fire hydrant maintenance isquite literallya lifeordeath proposition. The tsi flowmaster provides the most reliable and accurate flow and pressure measurements. A pressure gauge is placed on one hydrant to record the static pressure. The spreadsheet can be sorted and searched for results matching file name, hydrant, location, date, static, residual, flow and other variables. Quickly determine you water supply capabilities with our online application for graphing fire hydrant flow test information on a logritmic graph n 1. Extrapolated flow at 0 psi, 20 psi or any user defined pressure. Hydrant flow test needs a professional who is wellrounded with the nfpa guidelines on how to perform it. A fire hydrant flow test is performed for a specific area by using three fire hydrants. For the purpose of this blog we will only discuss how to perform a main capacity flow test, which is the two hydrant flow test.

Use new remote read with bleeder valve or direct reading on hydrantpro changeouts are easy. The program offers a picture field for each entry, so you can add a digital photo of each location to help remember the installation, or draw a sketch with measurements or other notes. Recommended practice for fire flow testing and marking of hydrants. Copy and paste hydrant flow test summary results to microsoft excel. Fire hydrant flow testing, safety inspections, valve.

Simply attach, switch on and take flow and pressure readings. Fire flow calculations software fireflow is a freeware, epanet based tool, which will calculate the available flow at network junctions while a minimal pressure is kept at demand junctions. Both tests are valuable, and correct or incorrect depending on the purpose of the test. Fire flow is the amount of water a main can deliver when needed for fighting a fire. One person at residual hydrant, one at the flow hydrant b. Pitot pressure and flow rates are calculated in accordance with nfpa 14, 2000 edition. Water pressure monitoring and management made simple. Hydrant flow and pressure test instrument model 342001. If you need flow testing, we offer two hydrant flow testing in accordance with iso standards. The xc2 hydrant module schedules and allows water or fire departments to test and graph their hydrant flow rates and to keep track of all of the information for community safety, insurance and liability issues.

Our fire flow pro system showcases the dependability of hydrant and water systems during their time of need. Fireflow tests the primary function of fireflow tests is to determine water pressure and flowproducing capabilities for fighting fires at any location within a. Our hydrant tracking and testing program was designed, like all of our software, to be operator friendly. Trimble unity software combined with telog wireless hydrant pressure recorders provide a giscentric cloud and mobile platform for monitoring system pressures, transients and trends, min, max and average pressure history at. Insure a reliable water supply for your customers, lower your iso score, and insure that you have enough water to fight a fire. Wireless hydrant pressure monitoring trimble water. Dhi software produces a range of software products for the modeling of water, from source to tap, from rainfall to the ocean, including mike net, a professional engineering software package for the simulation of steady flow and pressure distribution, extended period simulation of hydraulic and water quality behaviour within drinking water distribution systems. They rush to the fire hydrant, connect their hoseand no water comes out. A residual flow test helps determine water main capabilities before and after t.

Unlimited number of flow test locations and outlets flowed. Reasons for hydrant flow tests fire fighting agencies water system planning and design. The graph displays extrapolated flow at 0 psi, 20 psi and other user defined values of. There is existing software which we can also leverage to draw hydrant flow data that can guide us in designing automatic sprinkler systems. Our team has developed this software, for your company, based on the need to quickly and accurately produce summaries at the click of a button. Residual fire hydrant flow testing per nfpa 291 in addition to flow testing all hydrants in a system, hydrant. Periodic hydrant flushing is important to help maintain highquality water and water distribution systems. Hydrant flow test sprinkler services new york engineers. Fire hydrant installation and repair crisp ladew fire. The xc2 hydrant module schedules and allows water or fire departments to test and graph their. The current edition, which replaces and supersedes the 2016 version of the standard, is distinguished by including the metric formula for discharge through circular orifices. Hydrant flow testing is performed by flow testing out of 2. A fire hydrant test is critical in determining areas in your system which require special attention. Xc2 hydrant flow testing and flushing xc2 software.

Recommended practice for fire flow testing and marking of hydrants nfpa 291 provides guidance on fire flow tests and marking of hydrants in order to determine and indicate the relative available fire service water supply from hydrants and to identify possible deficiencies which could be corrected to ensure adequate fire flows as needed. Comprehensive flow testing may require specialized equipment and software. Use the one click export function to automatically export stored data into an excel spreadsheet. Flow test parameters and results are displayed in a scrollable summary spreadsheet. Static reading at the second pressure hydrant pressure in the system with no flow. Hydraulic calculation software for fire hydrant flow testing.

Aug 17, 2016 if you are performing fire flow tests of hydrants, use this test residual hydrant and flow hydrant are the same one. The community was devastated, 3,000 homes were lost. A main capacity test evaluates the water supply of the fire main at the location of the test hydrant. Sep 27, 2018 the standard for fire flow testing and marking of fire hydrants, nfpa 2912019. It tracks each hydrant from the date of purchase until salvage many years later.

This proves enough how unmatched we are in fire hydrant services. Items sold by usabluebook are intended for use only by professionals in the water and wastewater treatment industry. Water resources management offers professional water and wastewater management software for hydrant, meter, valve, manhole, cross connect, back flow, work orders and more. Nni hydrant data logger antitheft locking cover with chain has been designed to easily secure hydrant data loggers effectively with a fire hydrant. There is no limit on the number of flow test locations and outlets flowed. Six 6 monthly inspections which is a visual inspection to ensure there is no notable. The dynamic graph responds immediately to changes in all major hydrant flow test parameters. Our experienced personnel have developed and performed complete fire hydrant and valve programs on distribution systems of up to 1,000 fire hydrants. Time is of the essence when fighting a fire, and a fire hydrant that doesnt flow can cause deadly delays. The minimum requirements for servicing of fire hydrants are specified in as 1851 section 4, and this requires. Testing fire hydrants for improved fire safety searcheb. Trimble unity software combined with telog wireless hydrant pressure recorders provide a giscentric cloud and mobile platform for monitoring system pressures, and trends, min, max and average pressure history at any user defined interval. Many items sold by usabluebook require supplemental training, licenses or permits for proper use and may be harmful if not used properly.

It requires expertise, accurate calculations, and meticulous record keeping and should only be performed by qualified professionals. Recommended practice for fire flow testing and marking of hydrants, has been revised. Simplify hydrant recordkeeping with this easytouse software. Our software is designed for the water operator, not the design engineer. The awwa recommends all water utilities initiate a valve exercise program that requires all valves to be inspected and operated on a regular basis. The flow test results are depicted on graphs with a vertical axis scaled in arithmetic units and the horizontal axis in logarithmic units. All inspections, testing and maintenance functions are tracked throughout its lifetime. Fire hydrant flow testing tests available flow pressure, operability and hydrant reliability through an entire water supply system. Fireflow can run in a steady state mode or perform an extended period simulation eps. This application has auto adjusting axis divisions and automatically calculates avaliable flow or pressure at a single point.

Many fire departments and water utilities do not know how to flow a fire hydrant properly. Free hydrant flow test calculator that prints a professional single page report with flow graph. Always remember to flow test and inspect fire hydrants annually to ensure the operation of the hydrants in your system. The following information on fire hydrant operation and maintenance provides insight into this process.

234 386 63 1067 1267 1280 800 293 1541 1482 1577 390 902 810 158 854 1001 261 711 103 946 825 603 602 371 536 1280 617 719 938 1248